The PET-derived tumor-to-blood standard uptake ratio (SUR) is superior to tumor SUV as a surrogate parameter of the metabolic rate of FDG J van den Hoff, L Oehme, G Schramm, J Maus, A Lougovski, J Petr, ... EJNMMI research 3 (1), 1-8, 2013 | 73 | 2013 |
Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction G Schramm, J Langner, F Hofheinz, J Petr, B Beuthien-Baumann, ... Magnetic Resonance Materials in Physics, Biology and Medicine 26 (1), 115-126, 2013 | 58 | 2013 |
A method for model-free partial volume correction in oncological PET. F Hofheinz, J Langner, J Petr, B Beuthien-Baumann, L Oehme, ... EJNMMI research 2 (1), 16, 2012 | 48 | 2012 |
Arterial spin labeling for motor activation mapping at 3T with a 32-channel coil: reproducibility and spatial accuracy in comparison with BOLD fMRI H Raoult, J Petr, E Bannier, A Stamm, JY Gauvrit, C Barillot, JC Ferré Neuroimage 58 (1), 157-167, 2011 | 48 | 2011 |
An automatic method for accurate volume delineation of heterogeneous tumors in PET F Hofheinz, J Langner, J Petr, B Beuthien‐Baumann, J Steinbach, ... Medical physics 40 (8), 082503, 2013 | 47 | 2013 |
The spatial coefficient of variation in arterial spin labeling cerebral blood flow images HJMM Mutsaerts, J Petr, L Václavů, JW van Dalen, AD Robertson, ... Journal of Cerebral Blood Flow & Metabolism 37 (9), 3184-3192, 2017 | 45 | 2017 |
Correction of scan time dependence of standard uptake values in oncological PET J van den Hoff, A Lougovski, G Schramm, J Maus, L Oehme, J Petr, ... EJNMMI research 4 (1), 1-14, 2014 | 45 | 2014 |
Improving quality of arterial spin labeling MR imaging at 3 tesla with a 32‐channel coil and parallel imaging JC Ferré, J Petr, E Bannier, C Barillot, JY Gauvrit Journal of Magnetic Resonance Imaging 35 (5), 1233-1239, 2012 | 36 | 2012 |
Influence and compensation of truncation artifacts in MR-based attenuation correction in PET/MR G Schramm, J Langner, F Hofheinz, J Petr, A Lougovski, ... IEEE transactions on medical imaging 32 (11), 2056-2063, 2013 | 34 | 2013 |
Partial volume correction in arterial spin labeling using a Look‐Locker sequence J Petr, G Schramm, F Hofheinz, J Langner, J van den Hoff Magnetic resonance in medicine 70 (6), 1535-1543, 2013 | 30 | 2013 |
Comparison of arterial spin labeling registration strategies in the multi‐center GENetic frontotemporal dementia initiative (GENFI) HJMM Mutsaerts, J Petr, DL Thomas, E De Vita, DM Cash, MJP van Osch, ... Journal of Magnetic Resonance Imaging 47 (1), 131-140, 2018 | 28 | 2018 |
Photon vs. proton radiochemotherapy: effects on brain tissue volume and perfusion J Petr, I Platzek, F Hofheinz, HJMM Mutsaerts, I Asllani, MJP van Osch, ... Radiotherapy and Oncology 128 (1), 121-127, 2018 | 23 | 2018 |
Cerebral perfusion changes in presymptomatic genetic frontotemporal dementia: a GENFI study HJMM Mutsaerts, SS Mirza, J Petr, DL Thomas, DM Cash, M Bocchetta, ... Brain 142 (4), 1108-1120, 2019 | 21 | 2019 |
Early and late effects of radiochemotherapy on cerebral blood flow in glioblastoma patients measured with non-invasive perfusion MRI J Petr, I Platzek, A Seidlitz, HJMM Mutsaerts, F Hofheinz, G Schramm, ... Radiotherapy and Oncology 118 (1), 24-28, 2016 | 21 | 2016 |
Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers K Ambarki, A Wåhlin, L Zarrinkoob, R Wirestam, J Petr, J Malm, A Eklund American Journal of Neuroradiology 36 (10), 1816-1821, 2015 | 20 | 2015 |
Evaluation and automatic correction of metal-implant-induced artifacts in MR-based attenuation correction in whole-body PET/MR imaging G Schramm, J Maus, F Hofheinz, J Petr, A Lougovski, ... Physics in Medicine & Biology 59 (11), 2713, 2014 | 18 | 2014 |
Denoising arterial spin labeling MRI using tissue partial volume J Petr, JC Ferré, JY Gauvrit, C Barillot Medical Imaging 2010: Image Processing 7623, 76230L, 2010 | 13 | 2010 |
Template‐based approach for detecting motor task activation‐related hyperperfusion in pulsed ASL data J Petr, JC Ferré, H Raoult, E Bannier, JY Gauvrit, C Barillot Human brain mapping 35 (4), 1179-1189, 2014 | 12 | 2014 |
ExploreASL: an image processing pipeline for multi-center ASL perfusion MRI studies HJMM Mutsaerts, J Petr, P Groot, P Vandemaele, S Ingala, AD Robertson, ... NeuroImage 219, 117031, 2020 | 11 | 2020 |
Cortical microinfarcts in memory clinic patients are associated with reduced cerebral perfusion DA Ferro, HJJM Mutsaerts, S Hilal, HJ Kuijf, ET Petersen, J Petr, ... Journal of Cerebral Blood Flow & Metabolism 40 (9), 1869-1878, 2020 | 11 | 2020 |