Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study GB Higgs, JA Hanzlik, DW MacDonald, JL Gilbert, CM Rimnac, SM Kurtz, ... The Journal of arthroplasty 28 (8), 2-6, 2013 | 186 | 2013 |
Does taper size have an effect on taper damage in retrieved metal-on-polyethylene total hip devices? GB Higgs, DW MacDonald, JL Gilbert, CM Rimnac, SM Kurtz, AF Chen, ... The Journal of arthroplasty 31 (9), 277-281, 2016 | 71 | 2016 |
Trunnion failure of the recalled low friction ion treatment cobalt chromium alloy femoral head KL Urish, BR Hamlin, AY Plakseychuk, TJ Levison, GB Higgs, SM Kurtz, ... The Journal of arthroplasty 32 (9), 2857-2863, 2017 | 57 | 2017 |
Retrieval analysis of PEEK rods for posterior fusion and motion preservation SM Kurtz, TH Lanman, G Higgs, DW MacDonald, SH Berven, JE Isaza, ... European spine journal 22, 2752-2759, 2013 | 41 | 2013 |
Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty G Higgs, J Hanzlik, D MacDonald, W Kane, J Day, G Klein, J Parvizi, ... Metal-on-metal total hip replacement devices, 2013 | 41 | 2013 |
Implant Research Center Writing Committee Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a … GB Higgs, JA Hanzlik, DW MacDonald, JL Gilbert, CM Rimnac, SM Kurtz J Arthroplasty 28 (8 suppl), 2-6, 2013 | 29 | 2013 |
Hospital costs for unsuccessful two-stage revisions for periprosthetic joint infection SM Kurtz, GB Higgs, E Lau, RR Iorio, PM Courtney, J Parvizi The Journal of Arthroplasty 37 (2), 205-212, 2022 | 28 | 2022 |
Oxidation, damage mechanisms, and reasons for revision of sequentially annealed highly crosslinked polyethylene in total knee arthroplasty DW MacDonald, GB Higgs, AF Chen, AL Malkani, MA Mont, SM Kurtz The Journal of arthroplasty 33 (4), 1235-1241, 2018 | 27 | 2018 |
Microgrooved surface topography does not influence fretting corrosion of tapers in total hip arthroplasty: classification and retrieval analysis C Arnholt, D MacDonald, G Higgs, M Kraay, C Rimnac, S Kurtz, ... Symposium on Modularity and Tapers in Total Joint Replacement Devices, 99-112, 2016 | 26 | 2016 |
Oxidative properties and surface damage mechanisms of remelted highly crosslinked polyethylenes in total knee arthroplasty DW MacDonald, G Higgs, J Parvizi, G Klein, M Hartzband, H Levine, ... International orthopaedics 37, 611-615, 2013 | 26 | 2013 |
Patient perceptions of wearable and smartphone technologies for remote outcome monitoring in patients who have hip osteoarthritis or arthroplasties SM Kurtz, GB Higgs, Z Chen, WJ Koshut, JM Tarazi, AE Sherman, ... The Journal of Arthroplasty 37 (7), S488-S492. e2, 2022 | 18 | 2022 |
Total knee post-cam design variations and their effects on kinematics and wear patterns WM Mihalko, J Lowell, G Higgs, S Kurtz Orthopedics 39 (3), S45-S49, 2016 | 14 | 2016 |
Retrieval analysis of metal-on-metal total hip prostheses: characterizing fretting and corrosion at modular interfaces G Higgs, S Kurtz, J Hanzlik, D MacDonald, WM Kane, J Day, GR Klein, ... Orthopaedic Proceedings 95 (SUPP_15), 108-108, 2013 | 8 | 2013 |
Micro-grooved surface topography does not influence fretting corrosion of tapers in THA: classification and retrieval analysis CM Arnholt, R Underwood, D MacDonald, G Higgs, A Chen, G Klein, ... Drexel University, 2015 | 5 | 2015 |
Does visual inspection of the taper head/stem junctions in metal-on-metal hips adequately characterize material loss from corrosion and wear SB Kocagoz, RJ Underwood, DW MacDonald, GB Higgs, JS Day, ... San Antonio, TX, USA: Orthopedic research society, 2013 | 5 | 2013 |
Technical Note: Is Corrosion a Threat to the Strength of the Taper Connection in Femoral Components of Total Hip Replacements? GB Higgs, DW MacDonald, J Lowell, A Padayatil, WM Mihalko, RL Siskey, ... Corrosion 73 (12), 1538-1543, 2017 | 4 | 2017 |
Are 36+ mm diameter HXLPE bearings at risk of increased wear from modular taper corrosion with ceramic and CoCr heads? S Kurtz, D MacDonald, G Higgs, J Gilbert, GR Klein, M Mont, J Parvizi, ... Orthopaedic Proceedings 95 (SUPP_34), 387-387, 2013 | 4 | 2013 |
Patient perceptions of wearable and smartphone technologies for remote outcome monitoring in total knee arthroplasties SM Kurtz, GB Higgs, Z Chen, WJ Koshut, JM Tarazi, AE Sherman, ... The Journal of Knee Surgery 36 (12), 1253-1258, 2023 | 3 | 2023 |
In Vivo Performance of the Femoral Head-neck Taper Connection and Development of an Electrochemical Framework for Quantitative Corrosion Investigations GB Higgs Drexel University, 2020 | 1 | 2020 |
ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY AS A METHOD TO DISTINGUISH CORROSION SEVERITY AND DAMAGE MODES IN RETRIEVED FEMORAL HEADS GB Higgs, CM Rimnac, WM Mihalko, JL Gilbert, SM Kurtz Orthopaedic Proceedings 101 (SUPP_5), 142-142, 2019 | | 2019 |