Suivre
Joaquim Sousa
Joaquim Sousa
Instituto Politécnico de Coimbra, Instituto Superior de Engenharia de Coimbra, Engª Civil
Adresse e-mail validée de isec.pt
Titre
Citée par
Citée par
Année
Water distribution network design optimization: simulated annealing approach
MC Cunha, J Sousa
Journal of Water Resources Planning and Management 125 (4), 215-221, 1999
6691999
Hydraulic infrastructures design using simulated annealing
MC Cunha, J Sousa
Journal of Infrastructure Systems 7 (1), 32-39, 2001
1222001
Estimation of the benefits yielded by pressure management in water distribution systems
R Gomes, A Sá Marques, J Sousa
Urban Water Journal 8 (2), 65-77, 2011
1062011
WaterNetGen: an EPANET extension for automatic water distribution network models generation and pipe sizing
J Muranho, A Ferreira, J Sousa, A Gomes, AS Marques
Water Science and Technology: Water Supply 12 (1), 117-123, 2012
902012
Identification of the optimal entry points at District Metered Areas and implementation of pressure management
R Gomes, A Sá Marques, J Sousa
Urban Water Journal 9 (6), 365-384, 2012
872012
Pressure-dependent demand and leakage modelling with an EPANET extension–WaterNetGen
J Muranho, A Ferreira, J Sousa, A Gomes, AS Marques
Procedia Engineering 89, 632-639, 2014
832014
Robust design of water distribution networks for a proactive risk management
MC Cunha, JJO Sousa
Journal of Water Resources Planning and Management 136 (2), 227-236, 2010
662010
Hidráulica Urbana: Sistemas de abastecimento de água e de drenagem de águas residuais
JAA Sá Marques, JJO Sousa
Engenharia Sanitaria e Ambiental, 450, 2011
622011
Decision support system to divide a large network into suitable District Metered Areas
R Gomes, AS Marques, J Sousa
Water Science & Technology 65 (9), 1667-1675, 2012
612012
Technical performance evaluation of water distribution networks based on EPANET
J Muranho, A Ferreira, J Sousa, A Gomes, AS Marques
Procedia Engineering 70, 1201-1210, 2014
552014
District Metered Areas Design Under Different Decision Makers’ Options: Cost Analysis
R Gomes, ASA Marques, J Sousa
Water resources management 27 (13), 4527-4543, 2013
452013
Locating leaks in water distribution networks with simulated annealing and graph theory
J Sousa, L Ribeiro, J Muranho, AS Marques
Procedia Engineering 119, 63-71, 2015
392015
An optimization approach to wastewater systems planning at regional level
J Sousa, A Ribeiro, M da Conceição Cunha, A Antunes
Journal of Hydroinformatics 4 (2), 115-123, 2002
392002
Locating Leaks with TrustRank Algorithm Support
L Ribeiro, J Sousa, AS Marques, NE Simões
Water 7 (4), 1378-1401, 2015
292015
The influence of pressure/leakage relationships from existing leaks in the benefits yielded by pressure management
R Gomes, J Sousa, AS Marques
Water Utility Journal 5, 25-32, 2013
292013
Robust optimization methodologies for water supply systems design
J Marques, MC Cunha, J Sousa, D Savić
Drinking Water Engineering and Science Discussions 5 (1), 173-192, 2012
272012
Hidráulica urbana: sistemas de abastecimento de água
JAS Marques, JJ de Oliveira Sousa
Imprensa da Univ. de Coimbra, 2007
26*2007
Optimal Management of Water Distribution Networks with Simulated Annealing: The C-Town Problem
J Sousa, J Muranho, A Sá Marques, R Gomes
Journal of Water Resources Planning and Management 142 (5), 9, 2015
232015
Different Design Criteria for District Metered Areas in Water Distribution Networks
R Gomes, J Sousa, J Muranho, AS Marques
Procedia Engineering 119, 1221-1230, 2015
192015
Influence of future water demand patterns on the district metered areas design and benefits yielded by pressure management
R Gomes, J Sousa, AS Marques
Procedia Engineering 70, 744-752, 2014
192014
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20