Suivre
Hugo Bouchard
Titre
Citée par
Citée par
Année
GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform
S Hissoiny, B Ozell, H Bouchard, P Després
Medical physics 38 (2), 754-764, 2011
2542011
A stoichiometric calibration method for dual energy computed tomography
AE Bourque, JF Carrier, H Bouchard
Physics in Medicine & Biology 59 (8), 2059, 2014
1792014
On the characterization and uncertainty analysis of radiochromic film dosimetry
H Bouchard, F Lacroix, G Beaudoin, JF Carrier, I Kawrakow
Medical physics 36 (6Part1), 1931-1946, 2009
1692009
Ionization chamber‐based reference dosimetry of intensity modulated radiation beams
H Bouchard, J Seuntjens
Medical physics 31 (9), 2454-2465, 2004
1662004
The potential of dual‐energy CT to reduce proton beam range uncertainties
E Bär, A Lalonde, G Royle, HM Lu, H Bouchard
Medical physics 44 (6), 2332-2344, 2017
1502017
Detector dose response in megavoltage small photon beams. I. Theoretical concepts
H Bouchard, J Seuntjens, S Duane, Y Kamio, H Palmans
Medical physics 42 (10), 6033-6047, 2015
1312015
Ionization chamber gradient effects in nonstandard beam configurations
H Bouchard, J Seuntjens, JF Carrier, I Kawrakow
Medical physics 36 (10), 4654-4663, 2009
1172009
Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects
H Bouchard, Y Kamio, H Palmans, J Seuntjens, S Duane
Medical physics 42 (10), 6048-6061, 2015
862015
A general method to derive tissue parameters for Monte Carlo dose calculation with multi-energy CT
A Lalonde, H Bouchard
Physics in medicine & biology 61 (22), 8044, 2016
832016
Experimental validation of two dual‐energy CT methods for proton therapy using heterogeneous tissue samples
E Bär, A Lalonde, R Zhang, KW Jee, K Yang, G Sharp, B Liu, G Royle, ...
Medical physics 45 (1), 48-59, 2018
732018
Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry
J Desroches, H Bouchard, F Lacroix
Medical Physics 37 (4), 1565-1570, 2010
662010
Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry
H Benmakhlouf, H Bouchard, A Fransson, P Andreo
Physics in Medicine & Biology 56 (22), 7179, 2011
632011
Reference dosimetry using radiochromic film
F Girard, H Bouchard, F Lacroix
Journal of applied clinical medical physics 13 (6), 339-353, 2012
612012
Optimized I-values for use with the Bragg additivity rule and their impact on proton stopping power and range uncertainty
E Bär, P Andreo, A Lalonde, G Royle, H Bouchard
Physics in Medicine & Biology 63 (16), 165007, 2018
522018
Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors
Y Kamio, H Bouchard
Physics in Medicine & Biology 59 (17), 4973, 2014
482014
Investigation of three radiation detectors for accurate measurement of absorbed dose in nonstandard fields
E Chung, H Bouchard, J Seuntjens
Medical physics 37 (6Part1), 2404-2413, 2010
462010
A Monte Carlo method to evaluate the impact of positioning errors on detector response and quality correction factors in nonstandard beams
H Bouchard, J Seuntjens, I Kawrakow
Physics in Medicine & Biology 56 (8), 2617, 2011
412011
A theoretical comparison of tissue parameter extraction methods for dual energy computed tomography
JÉ Tremblay, S Bedwani, H Bouchard
Medical physics 41 (8Part1), 081905, 2014
402014
Lorentz force correction to the Boltzmann radiation transport equation and its implications for Monte Carlo algorithms
H Bouchard, A Bielajew
Physics in Medicine & Biology 60 (13), 4963, 2015
392015
Reference dosimetry in the presence of magnetic fields: conditions to validate Monte Carlo simulations
H Bouchard, J de Pooter, A Bielajew, S Duane
Physics in Medicine & Biology 60 (17), 6639, 2015
372015
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20