ada fort
ada fort
professore di Misure Elettriche ed Elettroniche, Università di Siena
Verified email at dii.unisi.it
Title
Cited by
Cited by
Year
Soft fault detection and isolation in analog circuits: some results and a comparison between a fuzzy approach and radial basis function networks
M Catelani, A Fort
IEEE Transactions on Instrumentation and Measurement 51 (2), 196-202, 2002
2162002
Method and device for reconstructing three-dimensional images of blood vessels, particularly coronary arteries, or other three-dimensional structures
L Masotti, R Pini, F Buzzigoli, A Fort
US Patent 6,169,917, 2001
1112001
Acoustic analysis of newborn infant cry signals
A Fort, C Manfredi
Medical engineering & physics 20 (6), 432-442, 1998
1061998
Fault diagnosis of electronic analog circuits using a radial basis function network classifier
M Catelani, A Fort
Measurement 28 (3), 147-158, 2000
1042000
SBT soft fault diagnosis in analog electronic circuits: a sensitivity-based approach by randomized algorithms
C Alippi, M Catelani, A Fort, M Mugnaini
IEEE Transactions on Instrumentation and measurement 51 (5), 1116-1125, 2002
1022002
A feedback strategy to improve the entropy of a chaos-based random bit generator
T Addabbo, M Alioto, A Fort, S Rocchi, V Vignoli
IEEE Transactions on Circuits and Systems I: Regular Papers 53 (2), 326-337, 2006
912006
A class of maximum-period nonlinear congruential generators derived from the Rényi chaotic map
T Addabbo, M Alioto, A Fort, A Pasini, S Rocchi, V Vignoli
IEEE Transactions on Circuits and Systems I: Regular Papers 54 (4), 816-828, 2007
852007
Automated selection of test frequencies for fault diagnosis in analog electronic circuits
C Alippi, M Catelani, A Fort, M Mugnaini
IEEE Transactions on instrumentation and Measurement 54 (3), 1033-1044, 2005
832005
Selectivity enhancement of SnO2 sensors by means of operating temperature modulation
A Fort, M Gregorkiewitz, N Machetti, S Rocchi, B Serrano, L Tondi, ...
Thin Solid Films 418 (1), 2-8, 2002
832002
Simplified models for SnO2 sensors during chemical and thermal transients in mixtures of inert, oxidizing and reducing gases
A Fort, M Mugnaini, S Rocchi, MB Serrano-Santos, V Vignoli, R Spinicci
Sensors and Actuators B: Chemical 124 (1), 245-259, 2007
722007
Model and experimental characterization of the dynamic behavior of low-power carbon monoxide MOX sensors operated with pulsed temperature profiles
S Bicelli, A Depari, G Faglia, A Flammini, A Fort, M Mugnaini, A Ponzoni, ...
IEEE Transactions on Instrumentation and Measurement 58 (5), 1324-1332, 2009
652009
Metal-oxide nanowire sensors for CO detection: Characterization and modeling
A Fort, M Mugnaini, S Rocchi, V Vignoli, E Comini, G Faglia, A Ponzoni
Sensors and Actuators B: Chemical 148 (1), 283-291, 2010
632010
Parametric and non-parametric estimation of speech formants: application to infant cry
A Fort, A Ismaelli, C Manfredi, P Bruscaglioni
Medical engineering & physics 18 (8), 677-691, 1996
631996
CO sensing with SnO2-based thick film sensors: Surface state model for conductance responses during thermal-modulation
A Fort, S Rocchi, MB Serrano-Santos, M Mugnaini, V Vignoli, A Atrei, ...
Sensors and Actuators B: Chemical 116 (1-2), 43-48, 2006
432006
Tin oxide gas sensing: Comparison among different measurement techniques for gas mixture classification
A Fort, N Machetti, S Rocchi, MBS Santos, L Tondi, N Ulivieri, V Vignoli, ...
IEEE Transactions on Instrumentation and Measurement 52 (3), 921-926, 2003
432003
Design, modeling, and test of a system for atmospheric electric field measurement
A Fort, M Mugnaini, V Vignoli, S Rocchi, F Perini, J Monari, M Schiaffino, ...
IEEE Transactions on instrumentation and Measurement 60 (8), 2778-2785, 2011
422011
Surface State Model for Conductance Responses During Thermal-Modulation of SnO-Based Thick Film Sensors: Part I—Model Derivation
A Fort, S Rocchi, MB Serrano-Santos, R Spinicci, V Vignoli
Instrumentation and Measurement, IEEE Transactions on 55 (6), 2102-2106, 2006
412006
A fuzzy approach for soft fault detection in analog circuits
M Catelani, A Fort, C Alippi
Measurement 32 (1), 73-83, 2002
402002
A real-time two-dimensional pulsed-wave Doppler system
M Scabia, M Calzolai, L Capineri, L Masotti, A Fort
Ultrasound in medicine & biology 26 (1), 121-131, 2000
402000
The digital tent map: Performance analysis and optimized design as a low-complexity source of pseudorandom bits
T Addabbo, M Alioto, A Fort, S Rocchi, V Vignoli
IEEE Transactions on Instrumentation and Measurement 55 (5), 1451-1458, 2006
392006
The system can't perform the operation now. Try again later.
Articles 1–20