Follow
W. Vance Payne
W. Vance Payne
Verified email at nist.gov - Homepage
Title
Cited by
Cited by
Year
Design of a steady-state detector for fault detection and diagnosis of a residential air conditioner
M Kim, SH Yoon, PA Domanski, WV Payne
International journal of refrigeration 31 (5), 790-799, 2008
2212008
Performance of a residential heat pump operating in the cooling mode with single faults imposed
M Kim, WV Payne, PA Domanski, SH Yoon, CJL Hermes
Applied thermal engineering 29 (4), 770-778, 2009
1422009
Effects of non-uniform refrigerant and air flow distributions on finned-tube evaporator performance
JM Choi, WV Payne, PA Domanski
International Congress Refrigeration, 2003
832003
Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor
V Payne, DL O'neal
International Journal of Refrigeration 18 (2), 107-112, 1995
811995
Net-zero and beyond! Design and performance of NIST's net-zero energy residential test facility
AH Fanney, V Payne, T Ullah, L Ng, M Boyd, F Omar, M Davis, H Skye, ...
Energy and buildings 101, 95-109, 2015
742015
Sensitivity analysis of installation faults on heat pump performance
PA Domanski, HI Henderson, WV Payne
US Department of Commerce, National Institute of Standards and Technology, 2014
612014
Residential heat pump heating performance with single faults imposed
SH Yoon, WV Payne, PA Domanski
Applied thermal engineering 31 (5), 765-771, 2011
612011
A comparison of an R22 and an R410a air conditioner operating at high ambient temperatures
WV Payne, PA Domanski
602002
Potential benefits of smart refrigerant distributors
WV Payne, PA Domanski
William V. Payne, Piotr A. Domanski, 2003
552003
Effect of common faults on the performance of different types of vapor compression systems
Z Du, PA Domanski, WV Payne
Applied thermal engineering 98, 61-72, 2016
522016
Evaporation and condensation heat transfer performance of flammable refrigerants in a brazed plate heat exchanger
SC Palmer, WV Payne, PA Domanski
US Department of Commerce, Technology Administration, National Institute of …, 2000
492000
Energy use consequences of ventilating a net-zero energy house
LC Ng, WV Payne
Applied thermal engineering 96, 151-160, 2016
462016
Mass flow characteristics of R-407c through short-tube orifices
WV Payne, DL O'Neal
ASHRAE transactions 104, 197, 1998
451998
Normalized performance parameters for a residential heat pump in the cooling mode with single faults imposed
JM Cho, J Heo, WV Payne, PA Domanski
Applied Thermal Engineering 67 (1-2), 1-15, 2014
422014
Cooling mode fault detection and diagnosis method for a residential heat pump
M Kim, SH Yoon, WV Payne, PA Domanski
NIST Special Publication 1087, 2008
402008
Multiphase flow of refrigerant 410A through short tube orifices
WV Payne, DL O'Neal
ASHRAE transactions 105, 66, 1999
381999
Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor
DW Nutter, D ONeal, WV Payne
American Society of Heating, Refrigerating and Air-Conditioning Engineers …, 1996
381996
Development of the reference model for a residential heat pump system for cooling mode fault detection and diagnosis
M Kim, SH Yoon, WV Payne, PA Domanski
Journal of mechanical science and technology 24, 1481-1489, 2010
372010
Mass flow rate of R-410A through short tubes working near the critical point
Y Kim, V Payne, J Choi, P Domanski
International journal of refrigeration 28 (4), 547-553, 2005
312005
A mass flow rate correlation for refrigerants and refrigerant mixtures flowing through short tubes
V Payne, DL O'Neal
Hvac&R Research 10 (1), 73-87, 2004
312004
The system can't perform the operation now. Try again later.
Articles 1–20