Follow
Chathura Kumaragamage
Chathura Kumaragamage
Verified email at yale.edu
Title
Cited by
Cited by
Year
Long-term reproducibility of GABA magnetic resonance spectroscopy
J Near, YCL Ho, K Sandberg, C Kumaragamage, JU Blicher
Neuroimage 99, 191-196, 2014
812014
On the magnetic field dependence of deuterium metabolic imaging
RA de Graaf, AD Hendriks, DWJ Klomp, C Kumaragamage, D Welting, ...
NMR in Biomedicine 33 (3), e4235, 2020
632020
Water and lipid suppression techniques for advanced 1H MRS and MRSI of the human brain: Experts' consensus recommendations
I Tkáč, D Deelchand, W Dreher, H Hetherington, R Kreis, ...
NMR in Biomedicine 34 (5), e4459, 2021
442021
A non-invasive restraining system for awake mouse imaging
D Madularu, AP Mathieu, C Kumaragamage, LM Reynolds, J Near, ...
Journal of neuroscience methods 287, 53-57, 2017
432017
Dynamic multicoil technique (DYNAMITE) MRI on human brain
C Juchem, S Theilenberg, C Kumaragamage, M Mullen, L DelaBarre, ...
Magnetic resonance in medicine 84 (6), 2953-2963, 2020
122020
A new low-noise signal acquisition protocol and electrode placement for electrocochleography (ECOG) recordings
C Kumaragamage, B Lithgow, Z Moussavi
Medical & biological engineering & computing 53, 499-509, 2015
102015
Dynamic 1H‐MRS for detection of 13C‐labeled glucose metabolism in the human brain at 3T
M Dehghani, S Zhang, C Kumaragamage, P Rosa‐Neto, J Near
Magnetic resonance in medicine 84 (3), 1140-1151, 2020
92020
Development of an ultra low noise, miniature signal conditioning device for vestibular evoked response recordings
CL Kumaragamage, BJ Lithgow, Z Moussavi
Biomedical engineering online 13, 1-20, 2014
92014
In vivo proton observed carbon edited (POCE) 13C magnetic resonance spectroscopy of the rat brain using a volumetric transmitter and receive‐only surface coil …
C Kumaragamage, D Madularu, AP Mathieu, H De Feyter, MN Rajah, ...
Magnetic resonance in medicine 79 (2), 628-635, 2018
82018
Robust outer volume suppression utilizing elliptical pulsed second order fields (ECLIPSE) for human brain proton MRSI
C Kumaragamage, HM De Feyter, P Brown, S McIntyre, TW Nixon, ...
Magnetic Resonance in Medicine 83 (5), 1539-1552, 2020
72020
Investigation of a new weighted averaging method to improve SNR of electrocochleography recordings
CL Kumaragamage, BJ Lithgow, ZK Moussavi
IEEE Transactions on Biomedical Engineering 63 (2), 340-347, 2015
72015
A chronic in situ coil system adapted for intracerebral stimulation during MRI in rats
D Madularu, C Kumaragamage, AP Mathieu, P Kulkarni, MN Rajah, ...
Journal of neuroscience methods 284, 85-95, 2017
62017
Implementation of a gelatin model to simulate biological activity in the inner ear for Electrovestibulography (EVestG) validation
C Kumaragamage, R Edwards, Z Moussavi, B Lithgow
2013 35th Annual International Conference of the IEEE Engineering in …, 2013
42013
Minimum echo time PRESS‐based proton observed carbon edited (POCE) MRS in rat brain using simultaneous editing and localization pulses
C Kumaragamage, D Madularu, AP Mathieu, D Lupinsky, RA de Graaf, ...
Magnetic Resonance in Medicine 80 (4), 1279-1288, 2018
32018
ECLIPSE utilizing gradient‐modulated offset‐independent adiabaticity (GOIA) pulses for highly selective human brain proton MRSI
C Kumaragamage, HM De Feyter, P Brown, S McIntyre, TW Nixon, ...
NMR in Biomedicine 34 (1), e4415, 2021
22021
ECLIPSE Utilizing Gradient MOdulated Offset-Independent Adiabaticity (GOIA) Pulses for Human Brain Proton MRSI
C Kumaragamage, HM De Feyter, P Brown, S McIntyre, TW Nixon, ...
In Proceedings of the 28th Annual Meeting of the ISMRM2020, 2020
22020
J‐difference editing of GABA with extended echo‐times
J Near, C Kumaragamage
Proc. Intl. Soc. Mag. Reson. Med 23, 4687, 2015
22015
Design and realization of a multi‐coil array for B0 field control in a compact 1.5T head‐only MRI scanner
S Theilenberg, Y Shang, J Ghazouani, C Kumaragamage, TW Nixon, ...
Magnetic resonance in medicine 90 (3), 1228-1241, 2023
12023
Short symmetric and highly selective asymmetric first and second order gradient modulated offset independent adiabaticity (GOIA) pulses for applications in clinical MRS and MRSI
C Kumaragamage, A Coppoli, PB Brown, S McIntyre, TW Nixon, ...
Journal of Magnetic Resonance 341, 107247, 2022
12022
Construction and validation of multi-coil Technology for Accessible Head-Only Scanner
S Theilenberg, Y Shang, C Kumaragamage, S McIntyre, TW Nixon, ...
Proc Intl Soc Magn Reson Med 30, 0644, 2022
12022
The system can't perform the operation now. Try again later.
Articles 1–20