Mechanical and thermo-physical behaviour of concretes and mortars containing phase change material
T Lecompte, P Le Bideau, P Glouannec, D Nortershauser, S Le Masson
Energy and buildings 94, 52-60, 2015
1932015
Hygrothermal behavior of bio-based building materials including hysteresis effects: Experimental and numerical analyses
D Lelievre, T Colinart, P Glouannec
Energy and Buildings 84, 617-627, 2014
1532014
Numerical modeling of heat and mass transfer in porous medium during combined hot air, infrared and microwaves drying
P Salagnac, P Glouannec, D Lecharpentier
International Journal of heat and mass transfer 47 (19-20), 4479-4489, 2004
1462004
Thermoelectric behaviour of melt processed carbon nanotube/graphite/poly (lactic acid) conductive biopolymer nanocomposites (CPC)
Z Antar, JF Feller, H Noel, P Glouannec, K Elleuch
Materials Letters 67 (1), 210-214, 2012
1152012
Experimental and numerical analysis of the transient hygrothermal behavior of multilayered hemp concrete wall
T Colinart, D Lelièvre, P Glouannec
Energy and Buildings 112, 1-11, 2016
1022016
Influence of the setting process and the formulation on the drying of hemp concrete
T Colinart, P Glouannec, P Chauvelon
Construction and Building materials 30, 372-380, 2012
982012
Thermal conductivity enhancement of electrically insulating syndiotactic poly (styrene) matrix for diphasic conductive polymer composites
G Droval, JF Feller, P Salagnac, P Glouannec
Polymers for advanced technologies 17 (9‐10), 732-745, 2006
952006
Measurement of thermal properties of biosourced building materials
T Pierre, T Colinart, P Glouannec
International Journal of Thermophysics 35 (9), 1832-1852, 2014
732014
Experimental and numerical study of heat transfer across insulation wall of a refrigerated integral panel van
P Glouannec, B Michel, G Delamarre, Y Grohens
Applied Thermal Engineering 73 (1), 196-204, 2014
722014
Conductive polymer composites with double percolated architecture of carbon nanoparticles and ceramic microparticles for high heat dissipation and sharp PTC switching
G Droval, JF Feller, P Salagnac, P Glouannec
Smart materials and structures 17 (2), 025011, 2008
632008
Building renovation with prefabricated ventilated façade element: A case study
T Colinart, M Bendouma, P Glouannec
Energy and Buildings 186, 221-229, 2019
612019
Experimental and numerical study of insulation walls containing a composite layer of PU-PCM and dedicated to refrigerated vehicle
B Michel, P Glouannec, A Fuentes, P Chauvelon
Applied Thermal Engineering 116, 382-391, 2017
602017
Temperature dependence of sorption isotherm of hygroscopic building materials. Part 1: Experimental evidence and modeling
T Colinart, P Glouannec
Energy and Buildings 139, 360-370, 2017
582017
Modelling heat and mass transfer in deformable porous media: Application to bread baking
V Nicolas, P Salagnac, P Glouannec, JP Ploteau, V Jury, L Boillereaux
Journal of food engineering 130, 23-35, 2014
582014
Characterization of electrical and thermal properties of extruded tapes of thermoplastic conductive polymer composites (CPC)
JF Feller, P Chauvelon, I Linossier, P Glouannec
Polymer testing 22 (7), 831-837, 2003
572003
Experimental survey on the combination of radiating infrared and microwave sources for the drying of porous material
P Glouannec, D Lecharpentier, H Noel
Applied Thermal Engineering 22 (15), 1689-1703, 2002
472002
Experimental study on the hygrothermal behavior of a coated sprayed hemp concrete wall
T Colinart, P Glouannec, T Pierre, P Chauvelon, A Magueresse
Buildings 3 (1), 79-99, 2013
452013
Numerical and experimental characterization of a batch bread baking oven
JP Ploteau, V Nicolas, P Glouannec
Applied Thermal Engineering 48, 289-295, 2012
432012
Temperature dependence of sorption isotherm of hygroscopic building materials. Part 2: Influence on hygrothermal behavior of hemp concrete
T Colinart, P Glouannec, M Bendouma, P Chauvelon
Energy and Buildings 152, 42-51, 2017
422017
Conception of thermoelectric flux meters for infrared radiation measurements in industrial furnaces
JP Ploteau, P Glouannec, H Noel
Applied thermal engineering 27 (2-3), 674-681, 2007