Follow
Liam Morris
Liam Morris
Atlantic Technological University - Galway City
Verified email at gmit.ie
Title
Cited by
Cited by
Year
Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge
DA Steinman, Y Hoi, P Fahy, L Morris, MT Walsh, N Aristokleous, ...
Journal of biomechanical engineering 135 (2), 021016, 2013
1722013
3-D numerical simulation of blood flow through models of the human aorta
L Morris, P Delassus, A Callanan, M Walsh, F Wallis, P Grace, ...
1692005
A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)
L Morris, P Delassus, M Walsh, T McGloughlin
Journal of biomechanics 37 (7), 1087-1095, 2004
1662004
Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke
S Duffy, M Farrell, K McArdle, J Thornton, D Vale, E Rainsford, L Morris, ...
Journal of neurointerventional surgery 9 (5), 486-491, 2017
1132017
Per-pass analysis of thrombus composition in patients with acute ischemic stroke undergoing mechanical thrombectomy
S Duffy, R McCarthy, M Farrell, S Thomas, P Brennan, S Power, A O’Hare, ...
Stroke 50 (5), 1156-1163, 2019
1102019
3D reconstruction and manufacture of real abdominal aortic aneurysms: from CT scan to silicone model
BJ Doyle, LG Morris, A Callanan, P Kelly, DA Vorp, TM McGloughlin
1052008
Effects of flat, parabolic and realistic steady flow inlet profiles on idealised and realistic stent graft fits through Abdominal Aortic Aneurysms (AAA)
L Morris, P Delassus, P Grace, F Wallis, M Walsh, T McGloughlin
Medical Engineering & Physics 28 (1), 19-26, 2006
752006
An experimental evaluation of device/arterial wall compliance mismatch for four stent-graft devices and a multi-layer flow modulator device for the treatment of abdominal …
L Morris, F Stefanov, N Hynes, EB Diethrich, S Sultan
European Journal of Vascular and Endovascular Surgery 51 (1), 44-55, 2016
742016
Geometrical enhancements for abdominal aortic stent-grafts
DS Molony, A Callanan, LG Morris, BJ Doyle, MT Walsh, TM McGloughlin
Journal of Endovascular Therapy 15 (5), 518-529, 2008
552008
A review of the in vivo and in vitro biomechanical behavior and performance of postoperative abdominal aortic aneurysms and implanted stent-grafts
TJ Corbett, A Callanan, LG Morris, BJ Doyle, PA Grace, EG Kavanagh, ...
Journal of Endovascular Therapy 15 (4), 468-484, 2008
542008
Stent graft performance in the treatment of abdominal aortic aneurysms: the influence of compliance and geometry
L Morris, F Stefanov, T McGloughlin
Journal of biomechanics 46 (2), 383-395, 2013
522013
Experimental assessment of stress patterns in abdominal aortic aneurysms using the photoelastic method
L Morris, P O'Donnell, P Delassus, T McGloughlin
Strain 40 (4), 165-172, 2004
502004
Systematic review and patient-level meta-analysis of the streamliner multilayer flow modulator in the management of complex thoracoabdominal aortic pathology
N Hynes, S Sultan, A Elhelali, EB Diethrich, EP Kavanagh, M Sultan, ...
Journal of Endovascular Therapy 23 (3), 501-512, 2016
422016
In vitro evaluation of the effects of intraluminal thrombus on abdominal aortic aneurysm wall dynamics
F Ene, C Gachon, P Delassus, R Carroll, F Stefanov, P O’Flynn, L Morris
Medical engineering & physics 33 (8), 957-966, 2011
392011
Vascular graft
L Morris, T McGloughlin, P Delassus, M Walsh, T O'Brien, J Callanan
US Patent App. 11/391,474, 2006
392006
Injection-moulded models of major and minor arteries: the variability of model wall thickness owing to casting technique
T O'Brien, L Morris, M O'Donnell, M Walsh, T McGloughlin
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2005
372005
Computational fluid analysis of symptomatic chronic type B aortic dissections managed with the Streamliner Multilayer Flow Modulator
F Stefanov, S Sultan, L Morris, A Elhelali, EP Kavanagh, V Lundon, ...
Journal of vascular surgery 65 (4), 951-963, 2017
342017
An experimental investigation of the hemodynamic variations due to aplastic vessels within three-dimensional phantom models of the circle of Willis
P Fahy, P McCarthy, S Sultan, N Hynes, P Delassus, L Morris
Annals of biomedical engineering 42, 123-138, 2014
302014
Anatomically and dielectrically realistic microwave head phantom with circulation and reconfigurable lesions
B McDermott, E Porter, A Santorelli, B Divilly, L Morris, M Jones, ...
Progress In Electromagnetics Research B 78, 47-60, 2017
292017
An In Vitro Evaluation of Emboli Trajectories Within a Three-Dimensional Physical Model of the Circle of Willis Under Cerebral Blood Flow Conditions
P Fahy, F Malone, E McCarthy, P McCarthy, J Thornton, P Brennan, ...
Annals of biomedical engineering 43, 2265-2278, 2015
282015
The system can't perform the operation now. Try again later.
Articles 1–20