Conjugate heat transfer by natural convection, conduction and radiation in open cavities H Nouanegue, A Muftuoglu, E Bilgen International Journal of Heat and Mass Transfer 51 (25-26), 6054-6062, 2008 | 103 | 2008 |
Heat transfer by natural convection, conduction and radiation in an inclined square enclosure bounded with a solid wall HF Nouanegue, A Muftuoglu, E Bilgen International Journal of Thermal Sciences 48 (5), 871-880, 2009 | 86 | 2009 |
Numerical study of solar-wind tower systems for ventilation of dwellings HF Nouanégué, LR Alandji, E Bilgen Renewable Energy 33 (3), 434-443, 2008 | 79 | 2008 |
Heat transfer by convection, conduction and radiation in solar chimney systems for ventilation of dwellings HF Nouanégué, E Bilgen International Journal of Heat and Fluid Flow 30 (1), 150-157, 2009 | 70 | 2009 |
Energy calibration of HVAC sub-system model using sensitivity analysis and meta-heuristic optimization GL Martin, D Monfet, HF Nouanegue, K Lavigne, S Sansregret Energy and Buildings 202, 109382, 2019 | 18 | 2019 |
Energy model validation of heated outdoor swimming pools in cold weather HF Nouanegue, S Sansregret, LB Le Building Simulation 2011 12, 2463-2468, 2011 | 14 | 2011 |
Mathematical modeling of dual intake transparent transpired solar collector T Semenou, DR Rousse, B Le Lostec, HF Nouanegue, PL Paradis Mathematical problems in engineering 2015, 2015 | 10 | 2015 |
On-site performance of air source heat pumps B Le Lostec, HF Nouanegue 11th IEA Heat Pump Conference, paper O 2, 2014 | 4 | 2014 |
Extracted heat from geothermal boreholes: where does the energy come from HF Nouanegue, AS Shirazi, M Bernier 4th Canadian Solar Buildings Conference, Toronto, Ontario, 227-236, 2009 | 4 | 2009 |
Influence de la température ambiante et du flux géothermique sur le transfert thermique dans un puits géothermqiue vertical HF Nouanegue, P Peysson, V Costes, M Bernier | 3 | 2009 |
Calibration of EnergyPlus HVAC models using optimization G Larochelle Martin, D Monfet, HF Nouanegue, S Sansreret, K Lavigne International Building Performance Simulation Association, 2016 | 1 | 2016 |
CALIBRATION of energyplus HVAC models using optimization GL Martin, D Monfet, HF Nouanegue, S Sansreret, K Lavigne eSim 2016, 2016 | 1 | 2016 |
Étude comparative du couplage de collecteurs solaires avec une thermopompe T Semenou, B Le Lostec, HF Nouanègue, DR Rousse | | 2015 |
SGE: Software Presentation HF Nouanegue, A Daoud, K Lavigne, A Poulin, A Charette, S Lahala, ... Energy Systems Laboratory (http://esl. tamu. edu), 2013 | | 2013 |
Étude du transfert thermique conjugué dans les cavités rectangulaires en convection naturelle HF Nouanegué École Polytechnique de Montréal, 2008 | | 2008 |
Study of heat transfer in rectangular cavities combined with natural convection HF Nouanegue Dissertation Abstracts International 70 (01), 2008 | | 2008 |