Michael Constantinou
Michael Constantinou
Samuel P. Capen Professor, SUNY Distinguished Prof., University at Buffalo
Adresse e-mail validée de buffalo.edu
Titre
Citée par
Citée par
Année
Semi-active control systems for seismic protection of structures: a state-of-the-art review
MD Symans, MC Constantinou
Engineering structures 21 (6), 469-487, 1999
8171999
Teflon bearings in base isolation II: Modeling
M Constantinou, A Mokha, A Reinhorn
Journal of Structural Engineering 116 (2), 455-474, 1990
7171990
Passive and active structural vibration control in civil engineering
TT Soong, MC Costantinou
Springer, 2014
5492014
Energy dissipation systems for seismic applications: current practice and recent developments
MD Symans, FA Charney, AS Whittaker, MC Constantinou, CA Kircher, ...
Journal of structural engineering 134 (1), 3-21, 2008
5492008
Earthquake engineering: from engineering seismology to performance-based engineering
Y Bozorgnia, VV Bertero
CRC press, 2004
5142004
Passive energy dissipation systems for structural design and retrofit
MC Constantinou, TT Soong, GF Dargush
Multidisciplinary Center for Earthquake Engineering Research, 1998
4231998
Experimental and analytical investigation of seismic response of structures with supplemental fluid viscous dampers
MC Constantinou, MD Symans
National Center for earthquake engineering research, 1992
3581992
Teflon bearings in base isolation I: testing
A Mokha, M Constantinou, A Reinhorn
Journal of Structural Engineering 116 (2), 438-454, 1990
3481990
Behaviour of the double concave friction pendulum bearing
DM Fenz, MC Constantinou
Earthquake engineering & structural dynamics 35 (11), 1403-1424, 2006
3462006
Fractional-derivative Maxwell model for viscous dampers
N Makris, MC Constantinou
Journal of Structural Engineering 117 (9), 2708-2724, 1991
3361991
Performance of seismic isolation hardware under service and seismic loading
MC Constantinou, AS Whittaker, Y Kalpakidis, DM Fenz, GP Warn
Technical Rep. No. MCEER-07 12, 2007
3182007
Spherical sliding isolation bearings with adaptive behavior: experimental verification
DM Fenz, MC Constantinou
Earthquake Engineering and Structural Dynamics 37 (2), 185-205, 2008
3142008
Experimental study of friction-pendulum isolation system
A Mokha, MC Constantinou, AM Reinhorn, VA Zayas
Journal of Structural Engineering 117 (4), 1201-1217, 1991
2891991
Nonlinear dynamic analysis of 3-D-base-isolated structures
S Nagarajaiah, AM Reinhorn, MC Constantinou
Journal of Structural Engineering 117 (7), 2035-2054, 1991
2771991
Toggle-brace-damper seismic energy dissipation systems
MC Constantinou, P Tsopelas, W Hammel, AN Sigaher
Journal of Structural Engineering 127 (2), 105-112, 2001
2552001
Experimental study of FPS system in bridge seismic isolation
P Tsopelas, MC Constantinou, YS Kim, S Okamoto
Earthquake engineering & structural dynamics 25 (1), 65-78, 1996
2341996
Experimental study of seismic response of buildings with supplemental fluid dampers
MC Constantinou, MD Symans
The Structural Design of Tall Buildings 2 (2), 93-132, 1993
2281993
Development and evaluation of simplified procedures for the analysis and design of buildings with passive energy dissipation systems.
OM Ramirez
2022001
Seismic testing of a building structure with a semi‐active fluid damper control system
MD Symans, MC Constantinou
Earthquake Engineering & Structural Dynamics 26 (7), 759-777, 1997
2001997
Dynamic analysis of generalized viscoelastic fluids
N Makris, GF Dargush, MC Constantinou
Journal of Engineering Mechanics 119 (8), 1663-1679, 1993
1801993
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20