Suivre
Emmanouil Zoros
Emmanouil Zoros
Medical Physicist
Adresse e-mail validée de med.uoa.gr
Titre
Citée par
Citée par
Année
Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry
E Pappas, G Kalaitzakis, T Boursianis, E Zoros, K Zourari, EP Pappas, ...
Physics in Medicine & Biology 64 (22), 225009, 2019
392019
Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications
DN Makris, EP Pappas, E Zoros, N Papanikolaou, DL Saenz, ...
Physics in Medicine & Biology 64 (10), 105009, 2019
282019
On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning
EP Pappas, E Zoros, A Moutsatsos, V Peppa, K Zourari, P Karaiskos, ...
Physics in Medicine & Biology 62 (10), 4160, 2017
242017
Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements
E Zoros, A Moutsatsos, EP Pappas, E Georgiou, G Kollias, P Karaiskos, ...
Physics in Medicine & Biology 62 (18), 7532, 2017
232017
On the development of a comprehensive MC simulation model for the Gamma Knife Perfexion radiosurgery unit
EP Pappas, A Moutsatsos, E Pantelis, E Zoros, E Georgiou, M Torrens, ...
Physics in Medicine & Biology 61 (3), 1182, 2016
232016
On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis
E Pantelis, A Moutsatsos, C Antypas, E Zoros, P Pantelakos, L Lekas, ...
Physics in Medicine & Biology 63 (16), 165015, 2018
192018
Validation of PTV margin for Gamma Knife Icon frameless treatment using a PseudoPatient® Prime anthropomorphic phantom
EY Han, P Diagaradjane, D Luo, Y Ding, G Kalaitzakis, E Zoros, K Zourari, ...
Journal of applied clinical medical physics 21 (9), 278-285, 2020
62020
Dosimetric evaluation of the Leksell GammaPlan™ Convolution dose calculation algorithm
A Logothetis, E Pantelis, E Zoros, EP Pappas, A Dimitriadis, I Paddick, ...
Physics in Medicine & Biology 65 (4), 045011, 2020
62020
Investigation of dose-rate dependence at an extensive range for PRESAGE radiochromic dosimeter
EP Pappas, E Zoros, K Zourari, CI Hourdakis, P Papagiannis, P Karaiskos, ...
Radiotherapy and Oncology 123, S410-S410, 2017
42017
Monte carlo determination of correction factors for dosimetric measurements in gamma knife perfexion small fields
E Zoros, EP Pappas, A Moutsatsos, E Pantelis, C Paraskevopoulou, ...
Physica Medica 32, 237, 2016
32016
On source models for 192Ir HDR brachytherapy dosimetry using model based algorithms
E Pantelis, K Zourari, E Zoros, V Lahanas, P Karaiskos, P Papagiannis
Physics in Medicine & Biology 61 (11), 4235, 2016
32016
A robust method, based on a novel source, for performance and diagnostic capabilities assessment of the positron emission tomography system
AP Samartzis, IS Kandarakis, EP Kounadi, EN Zoros, E Skoura, ...
Hellenic Journal of Nuclear Medicine 17 (2), 97-105, 2014
32014
Dosimetric accuracy of the Convolution algorithm for Leksell Gamma Plan radiosurgery treatment planning: Evaluation in the presence of clinically relevant inhomogeneities
E Pantelis, A Logothetis, E Zoros, EP Pappas, P Papagiannis, I Paddick, ...
Journal of Applied Clinical Medical Physics 24 (5), e13903, 2023
22023
Evaluation of the accuracy of the electron transport algorithms of the MCNP6 and EGSnrc Monte Carlo codes using the Fano theorem
E Zoros, E Pappas, E Pantelis
Physica Medica: European Journal of Medical Physics 30, e113, 2014
22014
On the effect of dose delivery temporal domain on the biological effectiveness of central nervous system CyberKnife radiosurgery applications: Theoretical assessment using the …
A Moutsatsos, P Kouris, M Zoros, O Athanasiou, C Koutsarnakis, ...
Physics in Medicine & Biology 67 (13), 135004, 2022
12022
Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions
D Saenz, N Papanikolaou, E Zoros, E Pappas, M Reiner, LT Chew, ...
Journal of Radiosurgery and SBRT 7 (3), 223, 2021
12021
Personalized End-to-End QA in Cranial SRS: Evaluation of the Phantom-to-Patient Dosimetric Equivalency of a 3D Printed Phantom using Film Dosimetry
E Pappas, D Makris, E Zoros, G Kalaitzakis, T Boursianis, N Papanikolaou, ...
International Journal of Radiation Oncology, Biology, Physics 102 (3), e485-e486, 2018
12018
[OA153] EBT3 radiochromic film dosimetry in kV X-ray radiation therapy
E Prentou, P Papagiannis, E Pantelis, E Zoros, P Karaiskos
Physica Medica: European Journal of Medical Physics 52, 58-59, 2018
12018
EP-1438 Experimental determination of correction factors for reference dosimetry in Gamma Knife Perfexion
E Zoros, EP Pappas, K Zourari, E Pantelis, A Moutsatsos, G Kollias, ...
Radiother. Oncol. 123, S758-S759, 2017
12017
On the use of presage detectors for the dosimetry of helical tomotherapy small fields
A Moutsatsos, E Pantelis, C Antypas, L Petrokokkinos, EP Pappas, ...
Physica Medica 32, 332, 2016
12016
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20