Suivre
Dima Abi-Abdallah Rodriguez
Dima Abi-Abdallah Rodriguez
Adresse e-mail validée de u-psud.fr - Page d'accueil
Titre
Citée par
Citée par
Année
Alterations in human ECG due to the MagnetoHydroDynamic effect: a method for accurate R peak detection in the presence of high MHD artifacts
D Abi-Abdallah, V Robin, A Drochon, O Fokapu
2007 29th Annual International Conference of the IEEE Engineering in …, 2007
512007
Reference signal extraction from corrupted ECG using wavelet decomposition for MRI sequence triggering: application to small animals
DA Abdallah, E Chauvet, L Bouchet-Fakri, A Bataillard, A Briguet, ...
462006
Reference signal extraction from corrupted ECG using wavelet decomposition for MRI sequence triggering: application to small animals
D Abi-Abdallah, E Chauvet, L Bouchet-Fakri, A Bataillard, A Briguet, ...
Biomedical engineering online 5 (1), 11, 2006
462006
Effects of static magnetic field exposure on blood flow
D Abi Abdallah, A Drochon, V Robin, O Fokapu
The European Physical Journal Applied Physics 45 (01), 11301, 2009
272009
Cardiac and respiratory MRI gating using combined wavelet sub-band decomposition and adaptive filtering
D Abi-Abdallah, A Drochon, V Robin, O Fokapu
Annals of biomedical engineering 35 (5), 733-743, 2007
232007
Simultaneous pressure–volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment
DAA Rodriguez, E Durand, L de Rochefort, Y Boudjemline, E Mousseaux
Medical engineering & physics 37 (1), 100-108, 2015
172015
Estimating absolute aortic pressure using MRI and a one-dimensional model
M Khalifé, A Decoene, F Caetano, L de Rochefort, E Durand, D Rodríguez
Journal of biomechanics 47 (13), 3390-3399, 2014
172014
Pulsed magnetohydrodynamic blood flow in a rigid vessel under physiological pressure gradient
D Abi-Abdallah, A Drochon, V Robin, O Fokapu
Computer methods in biomechanics and biomedical engineering 12 (4), 445-458, 2009
132009
Left Ventricular Pressure-Volume Analysis: an example of function assessment on a sheep
D Rodriguez
Université Paris Sud, 2015
92015
Stationary Flow of Blood in a Rigid Vessel in the Presence of an External Magnetic Field: Considerations about the Forces and Wall Shear Stresses
A Drochon, V Robin, O Fokapu, DAA Rodriguez
Applied Mathematics 7, 130-136, 2016
52016
Extracting a reference signal for cardiac MRI gating: Experimental study for wavelet functions choice
O Fokapu, D Abi-Abdallah, A Briguet
Proc. of the International Workshop on Systems, Signals and Image Processing …, 2005
52005
Extracting a reference signal for cardiac MRI gating: Experimental study for wavelet functions choice
O Fokapu, D Abi-Abdallah, A Briguet
Proc. of the International Workshop on Systems, Signals and Image Processing …, 2005
52005
In vitro validation of non-invasive aortic compliance measurements using MRI
M Khalife, D Rodriguez, L de Rochefort, E Durand
Computer methods in biomechanics and biomedical engineering 15 (sup1), 83-84, 2012
32012
Magnetohydrodynamic flow of blood: Influence of the simplifying assumptions in calculations
DA Abdallah, A Drochon, V Robin, O Fokapu
Journal of Biomechanics, S269, 2008
32008
Pulsed magnetohydrodynamic blood flow in a rigid vessel
D Abi-Abdallah, V Robin, O Fokapu, A Drochon
Computer Methods in Biomechanics and Biomedical Engineering 10 (sup1), 159-160, 2007
32007
A. Pulsed magnetohydrodynamic blood flow in a rigid vessel.
DA Abdallah, V Robin, O Fokapu, A Drochon
32th Congrès de la Société de Biomécanique, 0
3*
A Review of Some Reference Analytic Solutions for the Magnetohydrodynamic Flow of Blood
A Drochon, M Beuque, DAA Rodriguez
22018
Removing the MHD artefacts from the ECG signal for cardiac MRI synchronization.
DA Abdallah, A Drochon, V Robin, P Poulet, O Fokapu
3rd European Medical and Biological Engineering Conference, 2005
2*2005
REMOVING THE MHD ARTIFACTS FROM THE ECG SIGNAL FOR CARDIAC MRI SYNCHRONIZATION
D Abi-Abdallah, A Drochon, V Robin, P Poulet, O Fokapu
FMBE Proceedings of the 3rd European Medical & Biological Engineering Conference, 2005
22005
A phantom study to evaluate the effects of a local sectional stiffness on aortic hemodynamics
K Rachid, D Rodriguez
Biomedical Physics & Engineering Express 3 (6), 065001, 2017
12017
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20